Q&A
about VFS-D7 Fusion Splicer
1>The
screen is dark after starting machine and the level lamp on electrodes
doesn’t work after opening windshield.
Solutions:
1)
Check whether the electrical outlet is inserted.
2)
Check whether the fuse is broken, and then replace the broken one.
2> “Exhausted Battery” is
displayed on the bottom of screen after starting
VFS-D7 and buzzer
works continually.
Solutions:
If use battery, then
replace the power supply.
3> The fiber can be reset as
normal, but when setting gap, fiber is immovable
on the screen and
“Replace Fiber” is displayed on the screen.
Solutions:
1) Press “”
to reset system.
2) Raise the windshield,
left and right clamps. The checking steps as follows:
3) Check whether broken
fiber exists.
4) Check whether cleaved
length is too short.
5) Check whether fiber
matches with V-groove.
4> The fiber can be reset
as normal, but when setting gap, fiber moves
backwards
continually, “Replace fiber” are displayed on screen.
Solutions:
Maybe there is too much
dust on the lens of microscope, clean the aclinic
and upright lens with
cotton swab until dust disappears, then try again.
5> The fiber can be reset
as normal, but when setting gap, “Replace fiber” is displayed on
screen.
Solutions:
1) Press “”
to reset system.
2) Raise the windshield,
left and right clamps. The checking steps as follows:
3) Check whether broken
fiber exists.
4) Check whether cleaved
length is too short.
5) Check whether fiber
matches with V-groove
6> When calibrating
automatically, fiber moves up and down, the screen’s
display stops at “Adjust core”.
Solutions:
1) Press “”
to reset system.
2) Check whether bare
fiber is clean.
3) Clean the dust of
V-groove.
4) Knock at the holder
until fiber is impacted, then try again.
7>The fiber can be reset as
normal, but when setting gap, “Bad left fiber’s surface” is
displayed.
Solutions:
1)
Observe fiber picture in screen, if the quality of left fiber’s
surface is bad,you
can remake surface and try again.
2)
Observe fiber picture in screen, if the quality of left fiber’s
surface is good,
maybe the value of “Setting surface” is too small, you can increase
it.
3)
After “Bad left fiber’s surface” is displayed, the screen becomes
dark;
Make sure
that windshield is covered well.
Raise
windshield, check whether the reeds are distorting, and then manage
it.
8> When
splicing the MM fiber, there is bubble in the process of arc.
Solutions: The difference between fiber’s core and envelope’s
refractive index
is too big. Operations as follows:
1)Consult
MM fiber’s arc program set by factory and confirm.
2)Do arc
test until “Moderate current” is displayed three times.
3)Splice
MM fiber; if there is bubble then modify arc parameter.
Operations are as follows:
1)
Enter the menu of arc parameter.
2)
Increase the value of “Pre-fusion time” until no bubble.
3)
Decrease the value of “Pre-fusion current” if no bubble and fiber
thins. |